ws sup720 3b supported line cards. 1 Ok. ws sup720 3b supported line cards

 
1 Okws sup720 3b supported line cards • A WS-SUP720 (a Supervisor Engine 720 manufactured with a PFC3A) can only support ERSPAN if it has hardware version 3

Using the compact flash adaptor, I did boot SUP. 2) with 458720K/65536K bytes of memory. D-Link Core Switch Line Cards; D-Link Core Switch Power. 1s for the feature support of OSPFv3 between PE & CE next month. (If not yet announced, then it will be shortly. Manuals;. 0 Ok 2 MSFC3 Daughterboard WS-SUP720 xxxxxx 2. 5 2 Supervisor Engine 720 (Hot) WS-SUP720-3B SAD0AAAAAAA. 57 A at 42 VDC . The variants of PFC3 distinguish the various Supervisor 720 families of engines. Here is the output of the show module on 6509. Catalyst 6500/Cisco 7600 Supervisor 720 Fabric MSFC3 PFC3B . Note The VSPA does not support OSM modules. The WS-F6K-DFC is only supported on the sup2. SXJ7. I have installed a X6704 4 port 10Gb card in slot 1 and powered up the system. Most of case, flash card (external) is bad or un-readable in somereason. Mod Ports Card Type Model Serial No. Its hardware-based feature set enables applications such as traditional IP forwarding, Layer 2 and Layer 3 Multiprotocol Label Switching (MPLS) VPNs. Once after a power outage, on Cisco Catalyst 6509-E, instead of the main module WS-SUP720-3BXL, only the backup module was launched. WS-X6148E-GE-45AT= Cat6500 48-Port PoE+ ready 10/100/1000 w/Jumbo Frame. We are using SS. Up to 1024 VRFs with a total of up to 1,000,000 routes per system. 1 Distributed Forwarding Card WS-F6700-DFC3B SAL1518CTZX 4. 5 Policy Feature Card 3 WS-F6K-PFC3B SAL1227WATL 2. Mark as New; Bookmark; Subscribe; Mute; Subscribe to RSS Feed; Permalink;. Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE with MSFC5 PFC4 - S-65-S720 . bin and s72033-adventerprisek9_wan-mz. 소개. Save this manual to your list of manuals. Presales have scoped 4x VS-S2T-10G cards to perform a seamless upgrade on the secondary unit first and then the primary. Quick Links Contacts;. Save. 3 Ok. bin command. The VS-S2T-10G is only compatible with the E series chassis so you cannot use it without a chassis upgrade: The WS-SUP720-3B would work, or you could use the VS-S720-10G-3C if you need 10gb ports on the supervisor card. This concerns only line cards. EN US. Could someone please able to help to confirm. Cisco_C6509 #dir slavesup-bootdisk: <<— displays standby. I've got a 6509 with two WS-SUP720-3B but one faulty (running IOS). The Supervisor Engine 720 family is supported on both operating systems–Cisco Catalyst OSRelease 15. However, continuously entered rommon mode. Step 2 Shut down the switch. WS-SUP720-3B Supervisor Engine 720 with PFC3B: Switch processor (SP):. The used Cisco WS-SUP720-3B is hardware-enabled. It never switches over to the RP. Cisco Catalyst 6513, WS-SUP32-GE-3B, Fan Tray (req. If you issue the show version command and the show module command, the output lists the parts that. MPLS in hardware to enable use of layer 3 VPNs and EoMPLS tunneling. The WS-X6148X2-RJ-45 (above, left) has 48 physical RJ-45 connectors. I attached another picture. Mod Online Diag Status---- ----- 1 Minor Error 2 24 CEF720 24 port 1000mb SFP WS-X6724-SFP SAL0AAAAAAA. So, no issue since your Sups. One option is to either move the connection to a different line card or to try reload line card in module 2 and see if it helps. Additionally, the PFC version on the VS-S720 would have to fall back to PFC-3B to interface with the Sup720. Regards. The WS-F6700-CFC is a daughtercard that provides centralized forwarding for the 67xx linecards. DWDM-XFP modules supported in SPA-1X10GE-L-V2 on SIP-600. > >Which brings up another question for me: Can you use any of the DFC3s >(WS-F6700-DFC3B, WS-F6700-DFC3A, WS-F6700-DFC3BXL) on any line card that >supports DFC3s? The WS-F6700-xxx DFCs only function on the WS-X67xx series line cards. the Integrated 720-Gbps Switch Fabric 2. On any modules running Cisco IOS software, save the running configuration. VSS - WS-SUP32-10GE-3B . 1 (1)SY on both active and backup supervisor modules. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1 of the EoL bulletin. Catalyst 6500シリーズスイッチで、システム全体の再起動ではなく、モジュール単体の再起動を行いたい場合には、以下のコマンドで行います。 にはスロット番号を入力します。 hw-module module reset 以下は、スロット1にインストールされたWS-X6716-10GEの再起動を行う例です。If you configure Cisco 6509 switch with Sup720-3B with WS-X6816-GBIC and. My question is what is the best way to swap out the supervisor module? Can the SUP720 be added as a standby module so that the . The amount of memory on both the routing engine and the Supervisor Engine module. However, when i check the buffer & Queue spec. The supervisor card is a WS-SUP720 in a WS-6513 chassis. In WS-SUP720-3B could. hotStandby support. the Cisco Catalyst 6500/cisco 7600 Series Supervisor Engine 720 Is A Family Of Supervisor Engine (s) Designed To Deliver Scalable Performance And Rich Set Of Ip Features In Hardware. SXF16. • A WS-SUP720 (a Supervisor Engine 720 manufactured with a PFC3A) can only support ERSPAN if it has hardware version 3. 3 Ok. 4 48 48-port 10/100/1000 RJ45 EtherModule WS-X6148A-GE-TX SAXXXXXXXXX. 3 Ok 3 Distributed Forwarding Card WS-F6700-DFC3BXL xxxxxx 5. 1Q standard. WS-F6700-CFC is the CFC card used on WS-X67xx Ethernet Modules. Interface Cards ; WS-SUP720-3B Catalyst 6500/Cisco 7600 Supervisor Engine Management Module (WS-SUP720-3B=) Zoom the image with the mouse . I believe this is the final release for WS-SUP720-3B which was launched in 2004, and VS-SUP720-10G-3C which. The CEF256 and dCEF256 series modules connect to fabric using 8 Gbps per channel and CEF720 series modules connect to it using 20 Gbps per channel. Use the command show bootvar to check that the boot variable is the same on both SUPs. GigabitEthernet3/1 is up (if_number 272) Corresponding hwidb fast_if_number 272. 0 degrees C) to 104 degrees F (40. We are planning a migration from two 6509-E chassis with a WS-SUP720-3B each, to the same two chassis with a VS-S720-10G each, to add VSS support to the system, and I have a couple of questions: I've been looking for some information about a possible "hot" migration with no risk of l. NAME: "2", DESCR:. Table 1. See more04-04-2017 06:36 AM. It can also be used as a regular 48 ports 10/100 line card in a first deployment stage with the possibility of extending to a future 96 ports of 10/100. The biggest difference we have seen between the 3B and 3BXL was the amount of BGP routes that can be handled. The 6500s on our network run on WS-SUP720-BASE supervisor modules with the MSFC3 daughter card. Each family may have 2 access cards. 7 Ok > 5 Policy Feature Card 3 WS-F6K-PFC3BXL SAL1102DGJY 1. 2 (1) Supervisor II with Cisco IOS Software Release 12. Router Supervisor Engine and Route Switch Processor. 5 PwrDown. 6 Ok 5 MSFC3 Daughterboard WS-SUP720 SAL1645RKPG 5. (policy feature card on the supervisor engine) or DFCs (distributed feature cards on the. sw01#show redundancy Configured Redundancy Mode = sso Operating Redundancy Mode = rpr sw01#show mod 5 2 Supervisor Engine 720 (Cold) WS-SUP720-3B SAL12. WS-SUP720-3B sup is EOL as well. They are claiming that they gave us sup720-3bxl but the show inventory and show module displays sup720-3b only. I also have following line cards and not srue if they are also EOL. With hardware-enabled forwarding for IPv4, IPv6 and. Cisco announces the end-of-sale and end-of life dates for the Cisco Catalyst 6500 Series Supervisor Engine 720-3B/3BXL and Associated. Which brings up another question for me: Can you use any of the DFC3s (WS-F6700-DFC3B,. Its hardware-based set of features allows for the deployment. 1Q . 6 MSFC3 Daughterboard WS-SUP720 SAL10456T9P 2. RSP720 with 10GE Uplink Ports Chapter 2 Route Switch Processors and Supervisor Engines Supported Chassis, Line Cards, and Modules The RSP720 supports the following Cisco 7600 chassis, line cards and modules: •. 3 Centralized Forwarding Card WS-F6700-CFC SAL1425KQGX 4. 5 Helpful. This line card not support . Hi everybody. 6 Policy Feature Card 3 WS-F6K-PFC3B SAL11456HCZ 2. Cisco 7606-S eliminates the need for a line-card slot for uplink ports. • WS-X6516-GBIC • WS-X6816-GBIC . (enabling 4-port 10GE and 48-port 10/100/1000 density line cards). When manually the diagnostic is executed, it rises. 3 Ok. already had one WS-SUO720-3B in the switch, We plugged it in and it. WS-X6716-10G-3CXL is ideally suited for LAN campus aggregation. 5 2 Supervisor Engine 720 (Active) WS-SUP720-3B . 6509A#show mod Mod Ports Card Type Model Serial No. So, to reitterate for my own clarification, the X6700-GE-TX with CFC is 100% compatible with the SUP-2T running. 3 Ok. You need a DFC3 to work with the sup720. 12. 2 Ok 2 Distributed Forwarding Card WS-F6700-DFC3C SAL1309KZPH 1. Note Use WS-F6K-PFC3B= to upgrade a WS-SUP720 with a PFC3B. Hello everyone, 4 weeks passed in debugging Cisco SUP720-3BXL crashes and I don't know what to do. I tried to turn on the power but its not happening. WS-F6700-DFC3A . 8 Ok > 5 MSFC3 Daughterboard WS-SUP720 SAL1101CZST 2. 6 2 Supervisor Engine 720 (Hot) WS-SUP720-3B SAL114990Q6. 0 Ok >>>> 5 Policy Feature Card 3 WS-F6K-PFC3B SAL10371CLL 2. Mod Online Diag Status ---- ----- 3 Pass08-03-2006 10:48 AM. The sup720 supports classic bus line cards and both (old) CEF256 and (new) CEF720 fabric line cards. 6 Ok. Many thanks JohnEngineering Tools Cool. WS-SUP720-3B Export Bookmark Overview Datasheet Parametric Crosses Overview Familiarize yourself with the fundamental general information, properties, and. Options. You will not be able to "buy new cards" because line cards supported by Sup720 are long end-of-support. See. Ryan _____Two 1-GB DRAM DIMMs (to be installed on the Supervisor Engine 720 switch processor and route processor) u0014 PFC3BXL only So, looks that you can use 1GB Dimm only WS-SUP720-3BXL supervisors. Cisco announces the end-of-sale and end-of-life dates for the Select Cisco Catalyst 6800/6500 Line Cards, Power Supplies, and Accessories. 5(1. Some of these VLANs are propagated to other switches in the network when you use the VLAN Trunking Protocol (VTP). On the Catalyst 6500/SUP720 that runs Cisco IOS, the SP will boot first and will then switch ownership to the RP. Supervisor support: Cisco Catalyst 6500 Supervisor Engine 32 (WS-SUP32-GE-3B and. WS-F6K-DFC= Dist Fwd Card for 65xx, 6816 Modules used with SUP2 See the Product Migration Options section below for detailed information on replacing this product. We have a few 6509's w/ WS-SUP720-3B sup engines, that will need to be replaced because of their EoX status. I have been looking everywhere for some info on the proper steps for doing this, however I have come up empty handed. The SUP720-3BXL and X6708-10GE with DFC3CXL upgrades all went fine and work correctly however the upgrade of the DFC on the X6748-GE-TX from a DFC3B to a DFC3BXL is not working and the line card ends up in a PwrDown status with the below logged to the console: *Jan 4 08:52:06. As the forwarding is centralized, the PFC performance, FIB entries, ACL lables are shared among the line cards that uses the Supervisor PFC for forwrding. 2, 512KB L2 CacheI´m experiencing a weird problem with a Catalyst 6509, 2XSUP7203BXL and 2XWS-X6704-10GE. Catalyst 6500/Cisco 7600 Supervisor 720 Fabric MSFC3 PFC3BXL . Buy or Renew. Cisco announces the end-of-sale and end-of life dates for the Cisco Catalyst 6500 Series Supervisor Engine 720-3B/3BXL and Associated Memory Modules Only. 5 Policy Feature Card 3 WS-F6K-PFC3B SAL1045726H 2. Folks. I am going to be performing an upgrade to the flash on my Core 6506-E switch. If I have interface cards with WS-F6700-DFC3B, can I upgrade the supervisor to a Sup720-3BXL, and keep the cards running DFC3B, until I upgrade them to DFC3BXL, or do I have to shutdown the system, when upgrading the the supervisors and interface card ??, so. You can generally use them as edge ports, but they often will not work/perform as well as some line card ports. The WS-F6K-DFC is only supported on the sup2. Customers Also Viewed These Support Documents. There are three flavors, PFC3A, PFC3B and PFC3BXL, correspond to WS-SUP720, WS-SUP720-3B and WS-SUP720-3BXL. We ordered more sup720s which came in as WS-SUP270-3Bs. 6 Policy Feature Card 3 WS-F6K-PFC3B SAL10457BQX 2. 7 Ok > 5 Policy Feature Card 3 WS-F6K-PFC3BXL SAL1102DGJY 1. The memory can be upgraded to 1 GB. 0 % First-trip repair success. 5 Ok. 1. 2, 512KB L2 Cache Last reset from s/w reset SuperLAT software (copyright 1990 by Meridian Technology Corp). Using the compact flash adaptor, I did boot SUP. Get the latest generation and end-of-sale Cisco products across all technologies. Cisco. 3 Ok. The variants of PFC3 distinguish the various Supervisor 720 families of engines. WS-F6K-DFC3B . hardened with support for features such as Port Security, CPU rate limiting, Multi-Path uRPF and a long list 802. sup720(config)#enable secret < password > [Choose a strong. Steps below) First of all, I inserted another compact flash into the disk0: and then entered boot disk0:s72033-ipservicesk9_wan-mz. Quick Links Contacts; Resources. We purchased a supervisor 720 (WS-SUP720-3B) and (2) (WS-6708-10G-3C) 8 port fiber modules and (1) WS-X6748-GE-TX) 48 port module to add to the switch. Routes 1,000,000 (IPv4); 500,000 (IPv6) Netflow Entries 256,000 Compare to Similar Items Table 2 shows the comparison of WS-SUP720-3B= and WS-SUP720-3BXL. Sup720/3B/3BXL There is currently no replacement product available for this product. P/S) VS-C6509E-S720-10G . It's pretty self explanatory for a tec. We have dual SUP720-3B's and 3x WS-X6748-GE-TX linecards. Because there are switch processor (SP) and route processor (RP) memory on the Supervisor Engine 720. Chinese; EN US; French; Japanese; Korean; PortugueseI am facing a problem with a cisco 6509 SUP720-3B that goes into rommon every time i restart. Using the software advisor, I cannot find an IOS compatible with the WS-SUP720-BASE, as it only gives me the WS-SUP720-3B as an option. 185 KB shared between 8 ports. Save this manual to your list of manuals. WS-F6700-DFC3A . 6 Policy Feature Card 3 WS-F6K-PFC3B SAL1015JMMM 2. Buy or Renew. 1 (20)E2. Router#. The system is a 6509-E running software version 15. 3 48 48 port 10/100 mb RJ45 WS-X6348-RJ-45 . If you configure Cisco 6509 switch with Sup720-3B with WS-X6816-GBIC and. -Power on Chasis. There was one failure message about unnsupported command but didnt take further notice. 5 Ok. 8 Ok > 5 MSFC3 Daughterboard WS-SUP720 SAL1101CZST 2. WS-X6K-S2-MSFC2= Catalyst 6500 Supervisor Engine 2, 2GE, plus MSFC-2/PFC-2, Spare . If the bug disappear then we will buy the memory for the other supervisor. S2TIBK9-15201SY IOS IP Base. We have dual SUP720-3B's and 3x WS-X6748-GE-TX linecards. This line card not support . Ethernet Services Line Cards; Online Diagnostic Tests; Acronyms; Search Find Matches in This Book. This two cards installed in cat6509E. WS-SUP720-3BXL. Cisco 7600 series routers support 4096 VLANs in accordance with the IEEE 802. --- ----- ----- ----- ----- 1 48 CEF720 48 port 1000mb SFP WS-X6748-SFP 2 48 CEF720 48 port 1000mb SFP WS-X6748-SFP 4 16 16 port 1000mb GBIC ethernet WS-X6416-GBIC 5 2 Supervisor Engine 720 (Hot) WS-SUP720-3B 6 2. My company has recently bought a VS-S720-10G-3C to replace with old sup720-3b, we have a 6509-E with two "WS-X6704-10GE (WS-F6700-CFC)" on slots 1&2. Without a DFC3, WS-X6516-GBIC hardware revisions 5. But also mentioned that &quot;Supervisor Engine 720 with any PFC (chassis will work in lowest common denominator mode). -Verification that New Modular is online. 0 Ok 2 Centralized Forwarding Card WS-F6700-CFC SAL1026TF24 2. See. But if you plan to use VSS, then your 6704 line card is incompatible with VSS. The Modular Cisco Catalyst switches, such as the 6500, 6000, 5500, 5000, 4500, and 4000 Series, support Online Insertion and Removal (OIR) or Hot Swap of all modules (power supplies, fan trays, Supervisor Modules and other Line and Service Modules). rommon 2> IP_SUBNET_MASK=<subnet mask for the above IP>. The X6704 is recognised but is powered off with a message stating that it is not supported. NorthSmart can provide support for WS-SUP720-3B hardware after the end of official support date, saving you money in the process Request a Quote. The 3B TCAM cannot handle that many IPv4 routes in hardware, causing the box to send anything above (192K) to the CPU. For rx SPAN, the line cards create a copy of the packet on receipt and direct the copy to the egress SPAN port. Sup720/3B/3BXL There is currently no replacement product available for this product. Actions performed: 1) Reboot 2) Re-seat the module. 1. Thanks, Madhu. However, during the careful installation I noticed that the thorn d. 3fa 10-100 card-wtdr computer networking:SUP7203B PFC incompatibility. 65. PFC3의 종류에따라 Supervisor 720 엔진 제품이 구분되는데, WS-SUP720, WS-SUP720-3B 및 WS-SUP720-3BXL에 해당하는 세 가지 선호 제품(PFC3A, PFC3B, PFC3BXL)이 있습니다. I will appreciate any help. 6 Ok. 2 . WS-SUP720-3B Sup 720 Engine WS-6704-10GE 4 port 10GE WS-X6768-GE-TX Fabric Enabled Line card Help rated! Thanks Gavin. If the line card supports it, you probably want a WS-F6700-DFC3B. We are getting a 6506 with the 3BXL for the purposes of supporting full. Talk to your SE/AM. Multiple daughter-card options for incremental upgrades and backward compatibility to support multiple generations of interface modules. When I power the unit on, the new supervisor comes up and working, but the 10G modules go to "PwrDown" state after some errors. A Chairde, Have a 7609 with a WS-SUP720-3BXL Supervisor Engine, and need to buy another chassis (7606) to increase capacity , and put some reliability into our network, if either chassis/SUP Card blow, we can change cards to other chassis. Obtaining Technical Assistance. 6 IEEE Voice Daughter Card WS-F6K-48-AF SAXXXXXXXXX 2. 6 MSFC3 Daughterboard WS-SUP720 SAL1015JMXX 2. Table 1. Trang chủ » Cửa hàng » CISCO MODULES & CARDS » Cisco 6500 Switch Modules » WS-SUP720-3B. 1 x 6509 with SUP720-3B running IOS 12. Our extensive inventory includes some of the most. 5 MSFC3 Daughterboard WS-SUP720 SAL1225UDVN 3. 6 Ok. 1 Ok 5 MSFC3 Daughterboard WS-SUP720 SAD092607JG 2. 0. The supervisor card is the least of your worries. The CAT6509 in question has WS-C6509 chassis, WS-SUP720-BASE sup engine, running in hybrid mode (CATOS 8. PFC3의 종류에따라 Supervisor 720 엔진 제품이 구분되는데, WS-SUP720, WS-SUP720-3B 및 WS-SUP720-3BXL에 해당하는 세 가지 선호 제품(PFC3A, PFC3B, PFC3BXL)이 있습니다. 4 Ok 6 MSFC3 Daughterboard WS-SUP720 SAL12330KS2 3. 3 24 CEF720 24 port 1000mb SFP WS-X6724-SFP SAD0AAAAAAA. 2(17b)SXA : VS-S720-10G-3C 04-04-2017 06:36 AM. Centralized Forwarding Card (WS-F6700-CFC) Use the command show bootvar to check that the boot variable is the same on both SUPs. started booting in a loop with these messages: Aug 16 15:54:08 MDT: %PFREDUN-SP-6-ACTIVE: Standby initializing for SSO mode. 2 Ok 6 Policy Feature Card 3 WS-F6K-PFC3B SAL12330EVD 2. Q. Had the existing configuration config saved in a txt file and replaced the supervisor. . Subscribe to RSS Feed; Mark Topic as New;. You need a DFC3 to work with the sup720. Cisco Catalyst WS-SUP720-3B Supervisor Engine Module Repair Service Center. Mod Online Diag Status. Produkt-Support. But I forgot its password, so I tried to recover password , FAILED First of all, I entered ROMmon mode using Ctrl+Break, and then enter "confreg 0x2142" command. (and other redundant cards) without powering down the router. UPC - 746320914848. Its hardware-based feature set enables applications such as traditional IP forwarding, Layer 2 and Layer 3 Multiprotocol Label Switching (MPLS) VPNs, Ethernet over. WS-SUP720-3B • Two Gigabit Ethernet uplink ports: port 1 supports a 1-Gbps SFP module; port 2 is configurable with either a 1-Gbps SFP module or a 10/100/1000-Mbps RJ-45 connector • Integrated 720-Gbps switch fabricThanks for pointing this out. WS-X6724-SFP= Catalyst 6500 24-port GigE Mod: fabric-enabled (Req. 2 MB shared between 8 ports. 6 MSFC3 Daughterboard WS-SUP720 SAL1015JMXX 2. Mod Online Diag Status---- -----. As the Recover a Supervisor Engine 720 from a Missing/Corrupted Cisco IOS Image or ROMmon Mode section mentions, the Supervisor Engine 720 does not support the. 5 2 Supervisor Engine 720 (Active) WS-SUP720-3B SAXXXXXXXXX. Quick Links Contacts; Resources. Distributed Forwarding Cards Supported with Supervisor Engine 2T. Note: Cisco Catalyst Supervisor Engine WS-SUP720-3B does not support VSS. 0 Ok. eliminates the need for a line-card slot for uplink ports. 0 Ok. The. 2(121) or later on the Cisco SAMI. The memory can be upgraded to 1 GB. Mod MAC addresses Hw Fw Sw Status. . We have a pair of 6509 E Cat Switches and now we need to implement VSS. Yes, they could support 68xx and 69xx and spin new ES cards (ES++), but that would be fairly expensive. Which brings up another question for me: Can you use any of the DFC3s (WS-F6700-DFC3B, WS-F6700. Here are the steps: rommon 1 > dev. 6 OkCisco WS-SUP720-3B Processor Guide - Page 58. Sup-bootflash refers to the internal flash memory which is. WS-SUP720-3B Cisco Catalyst 6500/7600 Supervisor Engine 720 Control Processor Fabric MSFC3 PFC3B. 1 Ok. Labels: Labels:. The supervisor card is the least of your worries. 6 Policy Feature Card 3 WS-F6K-PFC3B SAL1424KF0R 2. See. WS-SUP720-3B - IOS 12. 2 PassSpecifications: Cisco WS-SUP720-3B Supervisor Engine 720 integrates a high-performance 720 Gbps crossbar switch fabric with a forwarding engine in a single module, delivering 40 Gbps of switching capacity per slot (enabling 4-port 10GE and 48-port 10/100/1000 density line cards) With hardware-enabled forwarding for IPv4, IPv6 and MPLS, the system. If you configure Cisco 6509 switch with Sup720-3B with WS-X6816-GBIC and. EOL8147-Amended. Cisco Application :: WS-SUP720-3B SP DRAM Requirement For ACE30; Cisco WAN :: 7613 - Redundancy With WS-SUP720-3BXL Module;Buy genuine Cisco products for less. The internal CompactFlash, which is referred to as bootdisk: in command-line interface (CLI), is upgradable to 512 MB and 1 GB. WS-SUP720-3B or WS-SUP720 . 7) and later . Thanks both, The linked page helped, now I have: Chassis#1 5 2 Supervisor Engine 720 (Active) WS-SUP720-3B SAL1002A4BQ 6 2 Supervisor Engine 720 (Hot) WS-SUP720-3B SAD090303EU 5 0014. WS-SUP720-3B: CATALYST 6500 / CISCO 7600 SUPERVISOR 720 FABRIC MSFC3 PFC3B:. 5. SXJ2. Our routers provide access to applications and services, integrate technologies, and extend the life of your network. . 3 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE SAXXXXXXXXX. If the line card supports it, you probably want a WS-F6700-DFC3B. Supervisor 720 with CatOS 8. These port cards are supported only on the specified switch models and are not interoperable. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1. So my question is the Sup720-3b I am switching is out from production, can I pull out the disk 0 and place that disk 0 into the replacement s. 1 (1) Supervisor 720 with Cisco IOS Software 12. bin command. The software image upgrade is necessary when:we have WS-C6509E-S32-GE & WS-C6509-E-FWM-K9 switches which has 6509-E , Sup 720 ,and 6700 Series line card . Power Management and Environmental Monitoring, Determining Software Feature Support - compatible line cards. you should have a PFC3B as PFC3A should be in sup32Background Information. Buy & sell Cisco WS-SUP720-3BXL Supervisor Engine, WS-SUP720-3BXL Catalyst 6500/Cisco 7600 Supervisor Engine Management Module WS-SUP720-3BXL price, 45%-98% OFF GPL Global Price List. Supervisor Engine 720 (WS-SUP720-3BXL) is shipped with a factory-installed PFC3BXL daughter card (WS-F6K-PFC3BXL) and a factory-installed MSFC3 daughter card (WS-F6K-MSFC3). show power and show modules follow: #show power system power redundancy mode = redundant system power total = 2771. Bookmark; Subscribe; Mute; Printer Friendly Page; 1576. 1 Ok. 8 Centralized Forwarding Card WS-F6700-CFC SAL16138HQL 4. Thank you very much for your support Mark!!! 0 Helpful. Scalability Table Name WS-SUP720-3B WS-SUP720-3BXL VS-S720-10G-3C * VS-S720-10G-3CXL* VSS No No Yes Yesneed for a line-card slot for uplink ports. If it isn’t or if the config register isn’t the same a handy trick is to set the config reg to 0x2142 for example (which is the “skip config at boot up” value), save the config, the set the config reg to 0x2102 (which is the “normal” value) and. 0 % Inventory Accuracy. 2(121) or later on the Cisco SAMI. I already purchased a FAN tray, two power units and 3 line cards (2x mini GBICs, 1x RJ54 ports). It's new Cisco module without warranty and since first day it crashes when "minimal or complete diagnostic" is turned on during boot. rommon 3> confreg 0x2102. -Installation of new C6800-32P 48ports module. BENEFIT: Better performance, features, and lower in price. 1 x 6509-E with SUP720-3B running IOS 12. 3 IEEE Voice Daughter Card WS-F6K-48-AF SAD111504LD 2. managing to crash the whole box. 1 Ok 5 Policy Feature Card 3 WS-F6K-PFC3B SAL1028UJ5L 2. 8 Centralized Forwarding Card WS-F6700-CFC SAD101503DX 2. 1x. Interface Support LAN and WAN interface modules as applicable VSS No Uplinks 2 Gigabit IPv4 Routing In hardware Up to 400 Mpps**. Cisco. The Supervisor Engine 32 is offered with the policy feature card 3B (PFC3B), delivering the. 6148 ain't designed to do heavy lifting such as switch uplink. Note Supervisor Engine 32 does not support this hardware: • WS-SUP720-3B • WS-F6K-PFC3BXL—Policy Feature Card 3BXL (PFC3BXL) • Distributed Forwarding Cards (DFCs) (installed DFCs do not power up with a Supervisor Engine 32) • Switch Fabric Modules • These switching modules: – WS-X6704-10GE—4-port 10-Gigabit Ethernet XENPAK WS-X6704-10G is Line Card with 4x 10GE port. It was very helpful. meanwhile i have formatted a compact flash in the one that are working fine cop. The result of this design is more efficient use of available. 6 2 Supervisor Engine 720 (Active) WS-SUP720-3B SAD0AAAAAAA Cisco announces the end-of-sale and end-of-life dates for the Cisco Catalyst 6500 Series Supervisor Engine 720-10G-3C, Select 67xx Line Cards, and Accessories. Yes, they could support 68xx and 69xx and spin new ES cards (ES++), but that would be fairly expensive. Log In. 2 Ok. Supervisor Engine 720 제품군은 Cisco Catalyst OS® 및 Cisco IOS® 운영 체제 모두에서 지원됩니다. 05-14-2013 03:09 PM. EN US. The Link Does Not Come Up in the Sup720 Module with Line Cards WS-X6724-SFP and WS-X6748-SFP, Even After a Reboot The WS-X6724-SFP Module with DFC3A Resets in Cisco Catalyst 6500 Switches That Run Cisco IOS Software Speeds Supported by the 1000BASE-T(GLC-T) SFP Module on the Cisco Catalyst 3750 Series. Mod Ports Card Type Model. The PoE daughter cards can be installed either at the factory or in the field on select 10/100 and 10/100/1000 Ethernet switching modules to upgrade the Ethernet switching modules. The Policy. The Supervisor Engine 32 provides investment protection for current Cisco Catalyst 6500 Series and Cisco 7600 Series deployments by supporting all existing classic and Cisco Express Forwarding 256-based modules and enabling new applications. About three weeks ago, Cisco IOS 15. Now it will no ignore the config when it boots. Cisco Catalyst 6504 Enhanced Chassis Spare. The SP ROMMON is 8. WS-X6K-S2-MSFC2 . We had a failure of the standby SUP720 which took down only one of the linecards. Supervisor Engine 720 제품군은 Cisco Catalyst OS® 및 Cisco IOS® 운영 체제 모두에서 지원됩니다. Read moreSupport. Figure 4. Thanks!Cisco announces the end-of-sale and end-of life dates for the Cisco Catalyst 6500 Series Supervisor Engine 720-3B/3BXL Upgrades and Associated Bundles.